🚚Free Shipping $250+ | Ships in 2-5 Days (U.S.)

Products

BILLDA BLD-RM40R-YYY 40W UFO High Bay Emergency LED Driver | 100-347V | 90-Minute Backup

RESOURCES & DOWNLOADS

(0 Reviews)

$159.50

Details

Features

The BILLDA BLD-RM40R-YYY 40W UFO high bay emergency LED driver provides 90 minutes of battery backup for compatible 0-10V dimmable UFO LED high bay fixtures. This round emergency driver combines 100-347V AC input, 120-190V DC output, a rechargeable battery and an integrated junction box in a suspension-friendly enclosure.

  • 40W constant emergency output for compatible UFO high bay lighting.
  • 90-minute rated emergency runtime with a 24-hour recharge time.
  • 100-347V AC, 50/60Hz input and 120-190V DC emergency output.
  • Wireless remote test control included. Two AAA remote batteries are required and are not included.
  • Integrated junction box for fixture wiring connections.
  • Over-voltage, over-load and open-circuit protection.
  • UL Listed for field or factory installation; UL 924 and CSA C22.2 No. 141 compliance stated in the manufacturer specification.
  • CEC Title 20 / BC compliant, according to the supplied specification.
  • Supports pole and ring mounting arrangements shown in the installation guide.
  • 5-year warranty; battery pro-rated.

Ideal Applications

  • Compatible 0-10V dimmable UFO LED high bay fixtures
  • Warehouse and distribution center emergency lighting
  • Industrial and commercial high bay installations
  • Suspended lighting retrofits requiring integrated emergency battery backup

Compatibility & Operation

The emergency driver connects to the input of the compatible fixture driver and supplies DC power during emergency operation. The fixture driver must accept the emergency unit’s 120-190V DC output. Do not connect loads rated for AC input only.

Connect both DIM+ and DIM- to the UFO LED driver’s 0-10V dimming inputs. The manufacturer states that emergency operation will not function if these connections are omitted.

For the 40W configuration, the manufacturer specifies fixtures with input power below 300W and minimum dimmed input power below 35W. Its wiring diagrams also recommend emergency output of at least 20% of the fixture’s input power; 40W meets that recommendation for fixtures up to 200W. Confirm all of these conditions and complete system compatibility before purchase.

Specifications

Brand BILLDA
Model / MPN BLD-RM40R-YYY
Manufacturer Configuration BLD-RM40R1-190H
Product Type UFO High Bay Emergency LED Driver / Battery Backup
Emergency Output Power 40W constant power
Input Voltage 100-347V AC
Input Frequency 50/60Hz
Output Voltage 120-190V DC
Emergency Runtime 90 minutes
Battery Type Rechargeable lithium-ion (40W model in specification)
Recharge Time 24 hours; more than 24 hours before first use
Maximum Input Current 200mA
Maximum Input Power 15W
Emergency Test Control Wireless remote control included (R version)
Remote Batteries 2 × AAA, not included
Fixture Compatibility UFO high bay LED driver with 0-10V dimming and compatible 120-190V DC input
Fixture Power Conditions Below 300W; minimum dimmed input below 35W; also follow 20% output recommendation
Operating Temperature 5°C to 50°C (41°F to 122°F)
Location Rating For fixtures listed for dry, damp or wet locations; verify complete assembly
Protection Over-voltage; over-load; open-circuit
Junction Box Built-in integrated junction box
Mounting Methods Pole or ring mounting; see installation drawing
Dimensions (Manufacturer Drawing) 273.9 mm length; Ø146.2 mm; 144.3 mm side profile
Standards UL 924; CSA C22.2 No. 141
UL File Number E519224
Energy Compliance CEC Title 20; BC compliant
Warranty 5 years; battery pro-rated

Remote Testing

Point the remote at the indicator within a 45-degree reception angle. Press ON to test emergency operation; the fixture enters emergency mode and the indicator turns off. Press OFF to restore mains operation. The R-version indicator flashes red while charging, remains red when fully charged, and turns off during emergency discharge.

The manufacturer instructs users to perform a functional test every 30 days and a 90-minute discharge test annually. Allow at least one hour of charging before a circuit test; a full charge requires 24 hours.

Installation & Storage Notes

  • Requires an unswitched 100-347V AC, 50/60Hz supply and compatible grounded lighting equipment.
  • Connect the battery only after installation is complete and AC power is supplied.
  • For fixtures listed for dry, damp or wet locations, subject to suitability of the complete installed assembly and appropriate connectors. No numeric IP rating is specified in the supplied document.
  • The 40W lithium-ion configuration is rated for 5°C to 50°C (41°F to 122°F).
  • For an optional 12V DC sensor, use the emergency driver’s 12V supply, not the UFO fixture driver’s supply. The specification limits sensor current to below 30mA.
  • Charge for more than 24 hours before first use. During storage, recharge for 24 hours every six months; the manufacturer specifies a maximum storage period of one year.
  • Use the mounting method shown in the guide that suits the fixture and installation. Confirm the supplied mounting hardware before ordering.
  • Installation and servicing must be performed by qualified personnel. Follow the complete manufacturer instructions and disconnect normal and emergency power before servicing.

Warranty

5-year warranty, with pro-rated battery coverage.