The BILLDA BLD-RM40R-YYY 40W UFO high bay emergency LED driver provides 90 minutes of battery backup for compatible 0-10V dimmable UFO LED high bay fixtures. This round emergency driver combines 100-347V AC input, 120-190V DC output, a rechargeable battery and an integrated junction box in a suspension-friendly enclosure.
The emergency driver connects to the input of the compatible fixture driver and supplies DC power during emergency operation. The fixture driver must accept the emergency unit’s 120-190V DC output. Do not connect loads rated for AC input only.
Connect both DIM+ and DIM- to the UFO LED driver’s 0-10V dimming inputs. The manufacturer states that emergency operation will not function if these connections are omitted.
For the 40W configuration, the manufacturer specifies fixtures with input power below 300W and minimum dimmed input power below 35W. Its wiring diagrams also recommend emergency output of at least 20% of the fixture’s input power; 40W meets that recommendation for fixtures up to 200W. Confirm all of these conditions and complete system compatibility before purchase.
| Brand | BILLDA |
| Model / MPN | BLD-RM40R-YYY |
| Manufacturer Configuration | BLD-RM40R1-190H |
| Product Type | UFO High Bay Emergency LED Driver / Battery Backup |
| Emergency Output Power | 40W constant power |
| Input Voltage | 100-347V AC |
| Input Frequency | 50/60Hz |
| Output Voltage | 120-190V DC |
| Emergency Runtime | 90 minutes |
| Battery Type | Rechargeable lithium-ion (40W model in specification) |
| Recharge Time | 24 hours; more than 24 hours before first use |
| Maximum Input Current | 200mA |
| Maximum Input Power | 15W |
| Emergency Test Control | Wireless remote control included (R version) |
| Remote Batteries | 2 × AAA, not included |
| Fixture Compatibility | UFO high bay LED driver with 0-10V dimming and compatible 120-190V DC input |
| Fixture Power Conditions | Below 300W; minimum dimmed input below 35W; also follow 20% output recommendation |
| Operating Temperature | 5°C to 50°C (41°F to 122°F) |
| Location Rating | For fixtures listed for dry, damp or wet locations; verify complete assembly |
| Protection | Over-voltage; over-load; open-circuit |
| Junction Box | Built-in integrated junction box |
| Mounting Methods | Pole or ring mounting; see installation drawing |
| Dimensions (Manufacturer Drawing) | 273.9 mm length; Ø146.2 mm; 144.3 mm side profile |
| Standards | UL 924; CSA C22.2 No. 141 |
| UL File Number | E519224 |
| Energy Compliance | CEC Title 20; BC compliant |
| Warranty | 5 years; battery pro-rated |
Point the remote at the indicator within a 45-degree reception angle. Press ON to test emergency operation; the fixture enters emergency mode and the indicator turns off. Press OFF to restore mains operation. The R-version indicator flashes red while charging, remains red when fully charged, and turns off during emergency discharge.
The manufacturer instructs users to perform a functional test every 30 days and a 90-minute discharge test annually. Allow at least one hour of charging before a circuit test; a full charge requires 24 hours.
5-year warranty, with pro-rated battery coverage.
There are no reviews yet. Be the first one to write one.
There are no reviews yet. Be the first one to write one.